MP7681 M/S/T/Q transfer to the PLC during block scan
Format: %xxxx
Input: Bit 0 –
0: Transfer M functions to the PLC during block scan
1: Collect M functions and transfer them to the PLC after
block scan
Bit 1 –
0: Transfer T code to the PLC during block scan
1: Transfer last T code to the PLC after block scan
Bit 2 –
0: Transfer S or G code to the PLC during block scan
1: Transfer S or G code to the PLC after block scan.
Bit 3 –
0: Transfer FN19 outputs to the PLC during block scan
1: Transfer last FN19 outputs to the PLC after block scan.
Bit 4 – MP subfiles during block scan
0: MP subfiles are not activated during block scan
1: MP subfiles are activated during block scan