Command reference
R&S
®
ZNA
1473User Manual 1178.6462.02 ─ 29
Manual operation: See "Acq Delay/Fixed" on page 699
[SENSe<Ch>:]PULSe:PERiod <pulse period for pulse modulators and trigger outs>
Defines the (common) pulse period of the internal pulse generators and modulators.
Suffix:
<Ch>
.
Channel number
Parameters:
<pulse period for
pulse modulators and
trigger outs>
Pulse period [s]
Default unit: s
Options: R&S ZNA-K7
Manual operation: See "Pulse Period" on page 695
[SENSe<Ch>:]PULSe:PORT<Pt>:DELay
<pulse delay on pulse modulator>
Defines the port-specific delay of the pulses generated by the respective internal pulse
generator.
This setting only takes effect, if:
●
Internal Pulse Control is enabled
●
Fixed Duty Cycle is disabled ([SENSe<Ch>:]PULSe:FXDCycle[:STATe] OFF)
Suffix:
<Ch>
.
Channel number
<Pt> Port number
Parameters:
<pulse delay on pulse
modulator>
Pulse delay [s]
Default unit: s
Options: R&S ZNA<Freq>-B4<Pt> or R&S ZNA-B91
Manual operation: See "Pulse Delay/Pulse Width" on page 697
[SENSe<Ch>:]PULSe:PORT<Pt>:EXTernal:INPut:INVerted[:STATe] <Boolean>
If External Pulse Control is used, this defines the polarity of the incoming generator
pulses at PuMo In/Out <Pt>.
Suffix:
<Ch>
.
Channel number
<Pt> Port number
Parameters:
<Boolean> *RST: OFF (0)
Options: R&S ZNA-B91
SCPI command reference