Command reference
R&S
®
ZNA
1489User Manual 1178.6462.02 ─ 29
Manual operation: See "Optional Columns" on page 557
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>:POWer[:LEVel] <IntSourcePortPow>
Defines a port-specific power level for port <PortId> in sweep segment <Seg> of chan-
nel <Ch>.
Requires that a port-specific power level has been previously enabled using
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>[:STATe].
Suffix:
<Ch>
.
Channel number
<Seg> Sweep segment number
<PortId> Port number
Parameters:
<IntSourcePortPow> Power level for port <PortId> in sweep segment <Seg> of chan-
nel <Ch>
Default unit: dBm
Manual operation: See "Optional Columns" on page 557
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>[:STATe] <Boolean>
Enables a port-specific power level (base power) for port <PortId> in segment <Seg>
of channel <Ch>.
Suffix:
<Ch>
.
Channel number
<Seg> Sweep segment number
<PortId> Port number
Parameters:
<Boolean> OFF (0)
No port-specific power level for port <PortId> in segment <Seg>
of channel <Ch>.
If [SENSe<Ch>:]SEGMent:POWer[:LEVel]:CONTrol is set
to ON, the segment power level [SENSe<Ch>:
]SEGMent<Seg>:POWer[:LEVel] is used. Otherwise the
channel base power SOURce<Ch>:POWer<PhyPt>[:
LEVel][:IMMediate][:AMPLitude] is used.
ON (1)
The port-specific power level [SENSe<Ch>:]SEGMent<Seg>:
PORT<PortId>:POWer[:LEVel] is used for port <PortId> in
segment <Seg> of channel <Ch>.
*RST:
OFF
Manual operation: See "Optional Columns" on page 557