Reference Guide 282 Document #: LTRT-17939
Mediant MSBR
Command Description
call-duration
Call duration in seconds (-1 for auto, 0 for
infinite).
call-party {called|caller}
Test call party.
called-uri
Called URI.
calls-per-second
Calls per second.
dst-address
Destination address and optional port.
dst-transport
Destination transport type.
endpoint-uri
Endpoint URI ('user' or 'user@host').
ip-group-name
IP Group.
max-channels
Maximum concurrent channels for session.
password
Password for registration.
Play {disable|dtmf|prt}
Playback mode.
qoe-profile
Quality of Experience (QOE) Profile.
route-by {dst-address|ip-
group|tel-to-ip}
Routing method.
schedule-interval
0 disables scheduling, any positive number
configures the interval between scheduled
calls (in minutes).
sip-interface-name
SIP Interface.
test-duration
Test duration (minutes).
test-mode {continuous|once}
Test mode.
user-name
User name for registration.
Command Mode
Privileged User
Example
This example partially configures a test call rule that calls endpoint URI 101 at IP address
10.13.4.12:
(config-troubleshoot)# test-call test-call-table 0
(test-call-table-0)# called-uri 101
(test-call-table-0)# route-by dst-address
(test-call-table-0)# dst-address 10.13.4.12

Table of Contents

Other manuals for AudioCodes Mediant MSBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant MSBR Series and is the answer not in the manual?

AudioCodes Mediant MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediant MSBR Series
CategoryNetwork Router
LanguageEnglish

Related product manuals