76.10.2 ethernet cfm
This command enables tunneling for IEEE 802.1ag Ethernet Connectivity Fault
Management (CFM) protocols.
Syntax
# ethernet cfm aging-time <time in minutes>
# ethernet cfm debounce <packet number>
# ethernet cfm mep
Command Description
aging-time Sets the remote MEP aging time
time in minutes Defines the actual aging time in minutes [1-9999].
debounce Sets the status-reflection debounce counter.
packet number
Defines the number of port-down packets to receive before
blocking ports.
Command Mode
Privileged User
Example
This example enables tunneling for cdp.
(config-data)# ethernet l2tunnel cdp