EasyManuals Logo
Home>AudioCodes>Network Router>Mediant MSBR Series

AudioCodes Mediant MSBR Series User Manual

AudioCodes Mediant MSBR Series
801 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Reference Guide 5. Debug Commands
Version 7.2 55 Mediant MSBR
Examples
The debug capture is de-activated using the following existing commands:
# debug capture data physical stop 192.168.0.3 vrf vrf1
Trying to send capture to TFTP/FTP server , filename debug-
capture-data-16032014-154400
Finished
5.6.1.5 debug capture data physical insert-pad
This command makes a manual mark in the captured file.
Syntax
debug capture data physical insert-pad
Default
By default, capture is inactive.
Command Mode
Enable
Related Commands
NA
Examples
The following example inserts a manual mark in the captured file.
# debug capture data physical insert-pad
5.6.1.6 debug capture data physical target
This command defines the destination server for the captured packet file.
Syntax
debug capture data physical target ftp user <ftp username>
password <ftp password>
debug capture data physical target tftp
debug capture data physical target usb
Arguments Description
ftp Defines using an FTP server.
tftp Sends the capture to a TFTP server.

Table of Contents

Other manuals for AudioCodes Mediant MSBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant MSBR Series and is the answer not in the manual?

AudioCodes Mediant MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediant MSBR Series
CategoryNetwork Router
LanguageEnglish

Related product manuals