Reference Guide 358 Document #: LTRT-17939
Mediant MSBR
Example
This example configures caller ID as "Joe Do":
(config-voip)# gateway caller-display-info 0
(caller-display-info-0)# display-string Joe Doe
(caller-display-info-0)# presentation allowed
(caller-display-info-0)# activate
59.2.6 charge-code
This command configures the Charge Codes table, which lets you define metering tones.
Syntax
(config-voip)# gateway analog charge-code <Index>
(charge-code-<Index>)#
Command Description
Defines a descriptive name.
end-time-1, end-time-
2, end-time-3, end-
Defines the end of the time period in a 24 hour format.
pulse-interval-1,
pulse-interval-
2,pulse-interval-3,
Defines the time interval between pulses (in tenths of a
second).
pulses-on-answer-1,
pulses-on-answer-2,
pulses-on-answer-3,
Defines the number of pulses that the device generates
upon call answer.
Command Mode
Privileged User
Example
This example configures a Charge Code:
(config-voip)# gateway charge-code 0
(charge-code-0)# charge-code-name INT
(charge-code-0)# end-time-1 04
(charge-code-0)# pulse-interval-1 2
(charge-code-0)# activate
59.2.7 enable-caller-id
This command configures the Caller ID Permissions table, which lets you enable Caller ID
generation for FXS interfaces and detection for FXO interfaces, per port.