Reference Guide 516 Document #: LTRT-17939
Mediant MSBR
Example
This example defines one group:
(conf-shdsl)# group 0
73.4.4 pairs
This command selects the wire-pairs which participate in an SHDSL group.
Syntax
interface shdsl 0/0
group <group-id>
pairs <list of wire-pair numbers>
Command Description
Defines the wire-pair numbers (0 to 3), separated by commas.
Examples:
list of wire-pair
numbers
pairs 0
Defines a simple two-wire connection using the first
wire pair.
pairs 0,1
Defines a multiple pair (m-pair) connection using wire
pairs.
pairs 0,1,2,3 Defines a multiple pair (m-pair) connection using all
four wire-pairs. Pair 0 is the master pair for this
group.
Default
By default, four SHDSL groups are defined, each with a single wire-pair; the system will
attempt to detect changes on the physical medium and adapt configuration accordingly.
Command Mode
Privileged User
Example
This example defines a group of two wire-pairs:
(conf-shdsl-0)# pairs 0,1
73.4.5 termination
This command selects the type of line termination on an SHDSL group.
Syntax
interface shdsl 0/0
group <group-id>
termination {cpe|co}