Reference Guide 52 Document #: LTRT-17939
Mediant MSBR
Arguments Description
capture is stopped (using ctrl-c), the capture file is
uploaded, via TFTP, to the TFTP server specified in this
argument.
The TFTP server IP address specified in this argument
must be accessible from one of the data sub-system
network interfaces, so that the capture file will be uploaded
to the server successfully. Use ping test to make sure this
TFTP server is accessible. This argument is optional.
ftp server ip address This command provides support for sending debug
captures to an FTP server.
Note: This is only applicable to MSBR devices.
Default
NA
Command Mode
Enable
Related Commands
debug capture voip
Examples:
The following example starts a debug capture on the network interface vlan 77, with a
protocol filter (tcp), a host filter (192.168.0.15), and a port filter (80). The captured traffic will
be printed to the CLI session:
# debug capture data interface vlan 77 proto tcp host 192.168.0.15
port 80
The following example starts a debug capture on the network interface GigabitEthernet 0/0,
with a protocol filter (udp), no host filter, and no port filter. The captured traffic will be saved
to a temporary file, and will be sent, when ctrl-c is used, to the TFTP server at address
192.168.1.12. This server is accessible via network interface vlan 1:
# debug capture data interface GigabitEthernet 0/0 proto udp host
any port any tftp-server 192.168.0.15

Table of Contents

Other manuals for AudioCodes Mediant MSBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant MSBR Series and is the answer not in the manual?

AudioCodes Mediant MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediant MSBR Series
CategoryNetwork Router
LanguageEnglish

Related product manuals