July 2013 4.4 List of machine parameters 497
MP121.0 Nominal speed command output of the first spindle
Input: 0: No servo-controlled axis
1 to 8: Analog CMA output X66, X67
51 to 56: Digital CC outputs X51 to X56
80 to 85: Digital UEC outputs X80 to X85
RESET 617
MP121.1 Nominal speed command output of the second spindle
Input: 0: No servo-controlled axis
1 to 4: Analog CMA output X66, X67
51 to 56: Digital CCC outputs X51 to X56
80 to 85: Digital UEC outputs X80 to X85
RESET
MP130.x Y index of the machine parameters MP2xxx.y for the axes
Input: 0 to 17
PLC
RUN
615
MP131.x Y index of the machine parameters MP2xxx.y for the
spindle(s) in operating mode 0
Input: 0 to 17
PLC
RUN
617
MP131.0 Index for the first spindle
MP131.1 Index for the second spindle
MP132.x Y index of the machine parameters MP2xxx.y for the
spindle(s) in operating mode 1
Input: 0 to 17
PLC
RUN
617
MP132.0 Index for the first spindle
MP132.1 Index for the second spindle
MP210 Counting direction of position encoder output signals
Format: %xxxxxxxxxxxxxxxxxx
Input: Bit 0 to Bit 17 represent axis 1 to 18
0: Positive
1: Negative
REF 609
MP331.x Distance for the number of signal periods in MP332
Input: 0.0001 to +1.797693135E+308 [mm] or [°]
PLC
RUN
REF
607
MP332.x Number of signal periods for the distance in MP331
Input: 1 to +1.797693135E+308
PLC
RUN
REF
607
MP334.x Nominal increment between two fixed reference marks on
encoders with distance-coded reference marks
Input: 1 to 65 535
0: 1 000
PLC
RUN
REF
607
MP340.x Interpolation factor for external interpolation
Input: 0 to 99
0 = 1: No external interpolation
RESET 607
MP Function and input Software
version and
behavior
Page