528 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP3240.2 Analog spindle: Spindle jog voltage for gear shifting
(M4009/M4010)
Input: 0 to 9.999 [V]
Digital spindle: Motor speed for gear shifting (M4009/
M4010)
Input: 0 to 9.999 [1000 min
–1
]
MP3310 Limitation for spindle speed override
Input: 0 to 150 [%]
PLC
RUN
962
MP3310.0 Upper limit
MP3310.1 Lower limit
MP3350 Maximum permissible overshoot of the spindle speed in
percent of the nominal spindle speed
Input: 0 to 100 [%]
PLC
RUN
955
MP3351 Entry of an absolute value for the permissible overshoot of
the spindle speed
Input: 0.001 to 100000.000 [rpm]
0 = Monitoring off
PLC
RUN
955
MP3411.0-7 Ramp gradient of the spindle with M03 and M04 for gear
ranges 1 to 8
Input: Analog axes: 0 to 1.999 [V/ms]
Digital axes: 0 to 1.999 [1000 min
–1
/ms]
PLC
RUN
954
MP3412 Multiplication factor for MP3411.x
Input: 0.000 to 1.999
PLC
RUN
954,
970,
975,
979
MP3412.0 With M05
MP3412.1 With oriented spindle stop
MP3412.2 With tapping with floating tap holder
MP3412.3 With rigid tapping
MP3415 Overshoot behavior of the spindle with M03, M04 and M05
Input: 0 to 1000 [ms]
PLC
RUN
958,
958,
958,
958
MP3415.0 With M03, M04 and M05
MP3415.1 For oriented spindle stop
MP3415.2 With tapping
MP3415.3 With rigid tapping
MP3420 Spindle positioning window
Input: 0 to 360.0000 [°]
PLC
RUN
970
MP3430 Deviation of the reference mark from the desired position
(spindle preset)
Input: 0 to 360 [°]
PLC
RUN
970
MP3440.0-7 k
V
factor for spindle orientation for gear ranges 1 to 8
Input: 0.1 to 10 [(1000°/ min) /°]
PLC
RUN
970
MP Function and input Software
version and
behavior
Page