Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Replace the Heater Control.
SE Code: 14.81:10 Curing power regulator current too high
Problem description:
Heaters, Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Check heaters with a tester and replace heaters if necessary (shortcut).
3. Replace the Heater Control.
SE Code: 14.82:10 Curing power regulator shortcut
Problem description:
Heaters, Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Check heaters with a tester and replace heaters if necessary (shortcut).
3. Replace the Heater Control.
SE Code: 14.83:11 Curing power regulator open circuit
Problem description:
Heater Control to Curing Power Interconnect PCA Cable. Curing Power Interconnect PCA Curing Cable. Curing
Resistor.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Reseat/Replace the Heater Control to Curing Power Interconnect PCA Cables.
3. Reseat/Replace Curing Power Interconnect PCA Curing Cable.
4. Reseat/Replace all Curing Resistors connectors.
SE Code: 14.87:10 Curing power regulator OverTemp
Problem description:
ENWW Continuable and non-continuable error codes 89

Table of Contents

Other manuals for HP Latex 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Latex 300 Series and is the answer not in the manual?

HP Latex 300 Series Specifications

General IconGeneral
BrandHP
ModelLatex 300 Series
CategoryPrinter
LanguageEnglish

Related product manuals