Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Replace the Heater Control.
SE Code: 14.81:10 – Curing power regulator current too high
Problem description:
Heaters, Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Check heaters with a tester and replace heaters if necessary (shortcut).
3. Replace the Heater Control.
SE Code: 14.82:10 – Curing power regulator shortcut
Problem description:
Heaters, Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Check heaters with a tester and replace heaters if necessary (shortcut).
3. Replace the Heater Control.
SE Code: 14.83:11 – Curing power regulator open circuit
Problem description:
Heater Control to Curing Power Interconnect PCA Cable. Curing Power Interconnect PCA Curing Cable. Curing
Resistor.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Reseat/Replace the Heater Control to Curing Power Interconnect PCA Cables.
3. Reseat/Replace Curing Power Interconnect PCA Curing Cable.
4. Reseat/Replace all Curing Resistors connectors.
SE Code: 14.87:10 – Curing power regulator OverTemp
Problem description: