3. Run Service "Curing system monitor.
4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
5. Reseat/Replace Curing Resistors.
6. Reseat/Replace Curing Temperature Sensors.
7. Reseat/Replace Curing Pressure Sensor.
SE Code: 16.05:00 – Curing system: temperature sensor error
Problem description:
Curing Control PCA Temperature Sensors Cable Temp. Sensors.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Run Service "Curing system monitor".
2. Reseat/replace Curing Control PCA Temperature Sensors Cable.
3. Reseat/replace Temp. Sensors.
SE Code: 16.07:03 – Curing system: warm up timeout (uniformity)
Problem description:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing
Temperature Sensor, Curing Pressure Sensor.
Corrective action:
Service engineer:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within
the printer's operating specifications; it should be higher than 15C for printer operation. If this is the
case, increase the ambient temperature of the printer's location.
2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation
Guide.
3. Run Service "Curing system monitor.
4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
5. Reseat/Replace Curing Resistors.
6. Reseat/Replace Curing Temperature Sensors.
7. Reseat/Replace Curing Pressure Sensor.
SE Code: 16.11:10 – Curing System: Temperature sensor 1 failure or not connected
Problem description:
Curing Control PCA Sensors cable Temp. sensor 1.
96 Chapter 3 System error codes ENWW