Corrective action:
Call agent:
Restart the printer.
Service engineer:
1. Check the Printmech to SOL slit solenoid cable.
2. Check the slit solenoid.
3. Check the Printmech PCA.
SE Code: 12.38:10 Printmech: 5V line open circuit
Problem description:
The 5V cable from Printmech to PSU has a problem Printmech PCA is damaged PSU is damaged.
Corrective action:
Call agent:
Restart the printer.
Service engineer:
1. Check that DS7 Printmech LED is turned on. If it is not the case, replace the Printmech PCA.
2. If the problem persist, replace the PSU.
SE Code: 13.3:10 Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
Problem description:
The Printmech 12V_BULLI_2 to Vapor Removal PCA is out of range.
Corrective action:
Call agent:
Restart the printer.
Service engineer:
1. Check the Printmech cable to Vapor Removal PCA.
2. Check the Printmech PCA.
SE Code: 14.73:01 Curing power regulator V lower than 60: V lower than 60
Problem description:
Heater Control AC Input (RCCB, AC Voltage Outlet, AC Power Cord) Heater Control.
Corrective action:
Call agent:
1. Check that both Residual Circuit Breakers (RCCBs) are Powered and ON.
2. Check/Reseat both Power Cords.
Service engineer:
ENWW Continuable and non-continuable error codes 87