SE Code: 15.32:10 – PZ resistor 2: Cable or resistor shortcircuit
Problem description:
Cable or resistor shortcircuit.
Corrective action:
Service engineer:
▲
Check the PZ resistor 2 or cable shortcircuit.
SE Code: 15.33:10 – PZ resistor 3: Cable or resistor shortcircuit
Problem description:
Cable or resistor shortcircuit.
Corrective action:
Service engineer:
▲
Check the PZ resistor 3 or cable shortcircuit.
SE Code: 15.41:11 – PZ resistor 1: Not connected
Problem description:
PZ Heaters Cable PZ Resistor 1 Air Curtain and Printzone Heaters Control PCA.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Reseat/Replace Air Curtain and Printzone Heaters Control PCA to PZ Heaters cable.
2. Reseat/Replace PZ Resistor 1.
SE Code: 15.42:11 – PZ resistor 2: Not connected
Problem description:
PZ resistor 2 disconnected or damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
▲
Check that PZ 2 resistor is properly connected. If it is, then replace PZ 2 resistor.
SE Code: 15.43:11 – PZ resistor 3: Not connected
Problem description:
PZ resistor 3 disconnected or damaged.
ENWW Continuable and non-continuable error codes 91