If any of the resistive values is out of range, check that the problem is not caused by the cable measuring the
value directly at the heater connector (it’s necessary to remove the right cover, left cover, and rear cover to
access to the connectors):
Measuring Curing Modules Heaters
The resistive value of a curing module heater must be between 34.33 and 36.45 Ohms. If the value is not in
this range the heater must be changed.
All the curing modules heaters can be measured from the connector of one of the cables connected to the
Curing Power interconnect PCA (to have access to the connector, the left curing module cover must be
disassembled):
When the connector of cable below is in the position shown, the pins of the connector match with the position
of the heaters in the curing module:
ENWW Troubleshooting the printer heaters 53