Aerosol or other malfunction of Color Sensor prevents calibration.
Corrective action:
Service engineer:
1. Retry calibration.
2. Replace SOL.
SE Code: 98:03 – Potential Print Quality problem. Detected too many nozzles out
Problem description:
Check PH using the PH status plot.
Corrective action:
Service engineer:
▲
Use the printhead status plot to find out which printheads have a massive number of nozzles out, and
replace them.
ENWW Continuable and non-continuable error codes 141