Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
▲
Check that PZ 3 resistor is properly connected. If it is, then replace PZ 3 resistor.
SE Code: 15.51:03 – PZ resistor 1: Out of range
Problem description:
Resistor out of range.
Corrective action:
Service engineer:
▲
Measure the PZ 1 resistance. Replace in case of resistance out of range.
SE Code: 15.52:03 – PZ resistor 2: Out of range
Problem description:
Resistor out of range.
Corrective action:
Service engineer:
▲
Measure the PZ 2 resistance. Replace in case of resistance out of range.
SE Code: 15.53:03 – PZ resistor 3: Out of range
Problem description:
Resistor out of range.
Corrective action:
Service engineer:
▲
Measure the PZ 3 resistance. Replace in case of resistance out of range.
SE Code: 15.60:10 – PZ fan fault or not connected
Problem description:
Fan fault or not connected
Corrective action:
Service engineer:
▲
Check that the PZ fans are properly connected. If they are, then replace them.
SE Code: 15.61:10 – PZ fan 1 fault or not connected
Problem description:
PZ fan 1 disconnected or damaged.
92 Chapter 3 System error codes ENWW