Call agent:
▲
Restart the printer.
Service engineer:
▲
Replace module 4.
SE Code: 16.50:03 – Curing system: pressure calibration error
Problem description:
Silent SE: If there's already a valid pressure calibration in NVM, and new calibration values are out of range,
then FW will use the NVM values and show a silent SE in the printer log and service plot.
SE Code: 16.50:10 – Severe SE: Pressure calibration failure together with NVM
values = 0 (failure at first startup)
Problem description:
Pressure calibration failure.
Corrective action:
Service engineer:
▲
Check the tube (not kinked), and sensor cable. If they are OK, replace the sensor
SE Code: 16.51:01 – Curing system: pressure not reachable. Printer is limiting
working pressure
Problem description:
Silent SE. Customer symptoms are: Slower thput, and/or Lack of curing Printer limiting working pressure.
It might be due to: Target pressure too high for printer attitude environment, and/or curing fan degradation.
SE Code: 16.61:10 – Vapor removal system: vapor fans array 1 fault
Problem description:
Air Curtain and Printzone Heaters Control/Curing Control PCA (depending on SKU) to Air Curtain Fans, Cable
Air Curtain Fans.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Reseat/Replace Air Curtain and Printzone Heaters Control/Curing Control PCA to Air Curtain Fans Cable.
2. Check that all Air Curtain Fans rotate, and are unobstructed.
3. Reseat/Replace Air Curtain Fans.
SE Code: 16.70:10 – Air Curtain system: Box fan fault or disconnected
Problem description:
Air Curtain Box Fan, Air Curtain and Printzone Heaters Control PCA.
100 Chapter 3 System error codes ENWW