1. Check that OMAS sensor is well connected.
2. Replace OMAS sensor. .
3. Replace OMAS controller PCA. See
OMAS controller PCA on page 431.
SE Code: 50.6:11 – OMAS board: Media sensor board Power cable
Problem description:
OMAS Controller to Engine PCA cable does not seem to be connected. Power not connected. Problems with 5V
line.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check that the OMAS Controller to Engine PCA cable is not damaged.
2. Check that the OMAS Controller to Engine PCA cable is correctly connected to the Engine PCA and the
OMAS Controller Card.
SE Code: 50:14 – Firmware version mismatch between the OMAS Controller Card
and Hard Disk Drive
Problem description:
FW mismatch.
Corrective action:
Call agent:
▲
Check that the printer has the latest firmware version. If not, update the firmware to the latest version.
Service engineer:
▲
Replace the OMAS Controller Card.
SE Code: 50:17 – Advisory fw error in DSP or Engine code of the substrate advance
sensor component
Problem description:
FW mismatch.
Corrective action:
Call agent:
▲
Check that the printer has the latest firmware version. If not, update the firmware to the latest version.
Service engineer:
▲
Replace the OMAS Controller Card.
SE Code: 52:10 – Drop Detector switch On/Off failure
Problem description:
ENWW Continuable and non-continuable error codes 125