SE Code: 12.31:10 – Printmech: 24V Misc open circuit. Check Air pumps and Primer
valves switch
Problem description:
The 24V cable from Printmech to Air Pumps and Interconnect PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Air Pumps and to primer valves switch cable.
2. Check the Air Pumps.
3. Check the Primer valves switch.
4. Check the Printmech PCA.
SE Code: 12.32:10 – Printmech: 24V to Printzone fans open circuit
Problem description:
The 24V cable from Printmech to Printzone fans has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Printzone fans cable.
2. Check the Printzone fans.
3. Check the Printmech PCA.
SE Code: 12.33:10 – Printmech: 24V to Vacuum fans open circuit
Problem description:
The 24V cable from Printmech to Vacuum fans has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Vacuum fans cable.
2. Check the Vacuum fans.
3. Check the Printmech PCA.
ENWW Continuable and non-continuable error codes 85