1. Reseat/Replace Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA cables.
2. Reseat/Replace Vapor Resistors.
SE Code: 16.84:03 – Air Curtain steady resistor: Out of range
Problem description:
Air Curtain Resistors.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
▲
Reseat/Replace Air Curtain Resistors.
SE Code: 16.85:03 – Air Curtain burst resistor: Out of range
Problem description:
Air Curtain Resistors.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
▲
Reseat/Replace Air Curtain Resistors.
SE Code: 16.90:10 – Air Curtain: Temperature sensor failure or not conected
Problem description:
Air Curtain and Printzone Heaters Control/Curing Control PCA (depending on SKU) to Air Curtain Temperature
Sensor Cable, Air Curtain Temperature Sensor.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Reseat/Replace Air Curtain and Printzone Heaters Control/Curing Control PCA to Air Curtain
Temperature Sensor Cable.
2. Replace Air Curtain Temperature Sensor.
SE Code: 17.0:11 – PrintMech to Interconnect Power cable does not seem to be
connected
Problem description:
The power cable from Printmech to Interconnect PCA has a problem.
Corrective action:
102 Chapter 3 System error codes ENWW