1. Reseat/Replace Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA cables.
2. Reseat/Replace Vapor Resistors.
SE Code: 16.84:03 Air Curtain steady resistor: Out of range
Problem description:
Air Curtain Resistors.
Corrective action:
Call agent:
Restart the printer.
Service engineer:
Reseat/Replace Air Curtain Resistors.
SE Code: 16.85:03 Air Curtain burst resistor: Out of range
Problem description:
Air Curtain Resistors.
Corrective action:
Call agent:
Restart the printer.
Service engineer:
Reseat/Replace Air Curtain Resistors.
SE Code: 16.90:10 Air Curtain: Temperature sensor failure or not conected
Problem description:
Air Curtain and Printzone Heaters Control/Curing Control PCA (depending on SKU) to Air Curtain Temperature
Sensor Cable, Air Curtain Temperature Sensor.
Corrective action:
Call agent:
Restart the printer.
Service engineer:
1. Reseat/Replace Air Curtain and Printzone Heaters Control/Curing Control PCA to Air Curtain
Temperature Sensor Cable.
2. Replace Air Curtain Temperature Sensor.
SE Code: 17.0:11 PrintMech to Interconnect Power cable does not seem to be
connected
Problem description:
The power cable from Printmech to Interconnect PCA has a problem.
Corrective action:
102 Chapter 3 System error codes ENWW

Table of Contents

Other manuals for HP Latex 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Latex 300 Series and is the answer not in the manual?

HP Latex 300 Series Specifications

General IconGeneral
BrandHP
ModelLatex 300 Series
CategoryPrinter
LanguageEnglish

Related product manuals