3. Press OK if another PIP module needs to be calibrated.
3.4.3. Refill ink tubes: 3.3.3 Refill Ink Tubes on page 152
Description
For information see:
3.3.3 Refill Ink Tubes on page 152
4. Scan Axis Menu
4.1 Scan-Axis Test
Description
The purpose of this test is to diagnose a failure in the operation of Scan Axis components.
Perform the Scan-Axis Test after:
●
System Error Code 86:YX
●
System Error Code 42:YX
●
System Error Codes related to Scan-Axis shutdown or Carriage jam.
WARNING! All the cover sensors are disabled when in the diagnostic tests menu. If the carriage is moving it
will not stop if the window is open, so be very careful not to place your hands inside.
Procedure
NOTE: Perform this test with the Printheads and the Tubes System installed so that the values can be
compared correctly.
1. Go to Diagnostic test > 4. Scan Axis Menu > 4.1 Scan-Axis test.
2. The test starts to move the carriage along the scan axis, looking for a paper jam or some problem in the
system.
3. Finally, the test will display thru the front panel the diagnostic result. Press OK to restart the printer. If
the diagnostic test fails, along the test could appear a System Error. In this case, troubleshoot the
system error using
System error codes on page 65.
4.2 SAX Lubrication Health Check
Description
The purpose of this test is to check if the SAX lubrication is correct.
WARNING! All the cover sensors are disabled when in the diagnostic tests menu. If the carriage is moving it
will not stop if the window is open, so be very careful not to place your hands inside.
156 Chapter 4 Service Tests, Utilities, and Calibrations ENWW