1. Check cable Printmech to Vapor Removal PCA .
2. Check the Printmech PCA. .
SE Code: 12.4:10 – Printmech 24V_BULLI_1 to Vapor Removal PCA out of range
Problem description:
The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech cable to Vapor Removal PCA.
2. Check the Printmech PCA.
SE Code: 12.5:10 – Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans
and PZ fans failure
Problem description:
The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech cables to the ISS, Interconnect and PZ fans.
2. Check the Printmech PCA.
SE Code: 12.6:10 – Printmech: 42V to Carriage PCA failure
Problem description:
The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech cable to Carriage PCA.
2. Check the Printmech PCA.
SE Code: 12.7:10 – Printmech: Hannibal1 24V failure. Check APS relief valve, SVS
motor and Rack engage motor
Problem description:
ENWW Continuable and non-continuable error codes 77