The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the APS relief valve, SVS motor and Rack engage motor.
2. Check the Printmech PCA.
SE Code: 12.8:10 – Printmech: Hannibal2 24V failure. Check Spit-on roller motor
and Primer motor
Problem description:
The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Spit-on roller motor and Primer motor.
2. Check the Printmech PCA.
SE Code: 12.9:10 – Printmech: Hannibal3 24V failure. Check Inner lights array 1
Problem description:
The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Inner lights array 1.
2. Check the Printmech PCA.
SE Code: 12.10:10 – Printmech: Hannibal4 24V failure. Check Inner lights array 2
Problem description:
The 24V cable from Printmech to Inner lights array 2 has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
78 Chapter 3 System error codes ENWW