1. Check the Spit-on roller motor and Primer motor.
2. Check the Printmech PCA.
SE Code: 12.28:10 – Printmech: Hannibal3 24V open circuit. Check Inner lights
array 1
Problem description:
The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Inner lights array 1.
2. Check the Printmech PCA.
SE Code: 12.29:10 – Printmech: Hannibal4 24V open circuit. Check Inner lights
array 2
Problem description:
The 24V cable from Printmech to Inner lights array 2 has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Inner lights array 2.
2. Check the Printmech PCA.
SE Code: 12.30:10 – Printmech: 24V to Interconnect open circuit. Check TUR, Right
aerosol fan and Primer valves
Problem description:
The 24V cable from Printmech to Interconnect PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Interconnect cable.
2. Check the TUR, Right aerosol fan, and Primer valves.
3. Check the Printmech PCA.