Power regulator OverTemp.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. If the SE appears frequently, replace the Heater Control.
SE Code: 14.88:10 Curing power regulator overvoltage or shortcut
Problem description:
Regulator overvoltage or shortcut.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Check resistor module values, If they are ok, check installation.
SE Code: 14.89:10 Curing power regulator relay damaged
Problem description:
Heater Control.
Corrective action:
Service engineer:
1. Run Service "Curing system monitor".
2. Replace de Heater Control.
SE Code: 15.20:10 Cable or Resistor shortcircuit from any PZ or vapor resistor
Problem description:
Shortcircuit from Any PZ or vapor resistor.
Corrective action:
Service engineer:
Check the PZ resistors, the Vapor resistors, or cable shortcircuits. Replace the affected part.
SE Code: 15.31:10 PZ resistor 1: Cable or resistor shortcircuit
Problem description:
Cable or resistor shortcircuit.
Corrective action:
Service engineer:
Check the PZ resistor 1 or cable shortcircuit.
90 Chapter 3 System error codes ENWW