SE Code: 12.17:10 – Printmech: 42V to Scan motor failure
Problem description:
The 42V cable from Printmech to Scan motor has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Scan motor cable.
2. Check the Scan motor.
3. Check the Printmech PCA.
SE Code: 12.18:10 – Printmech: 42V to SOL slit solenoid failure
Problem description:
The 42V cable from Printmech to SOL slit solenoid has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to SOL slit solenoid cable.
2. Check the slit solenoid.
3. Check the Printmech PCA.
SE Code: 12.19:10 – Printmech: 5V line failure
Problem description:
The 5V cable from Printmech to PSU has a problem Printmech PCA is damaged PSU is damaged.
Call agent:
▲
Restart the printer.
SE Code: 12.20:10 – Printmech: 12V to Curing module PCA open circuit
Problem description:
The 12V cable from Printmech to Curing Control PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
ENWW Continuable and non-continuable error codes 81