Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to ISS, Interconnect, and PZ fans cables.
2. Check the Printmech PCA.
SE Code: 12.25:10 – Printmech: 42V to Carriage PCA open circuit
Problem description:
The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Carriage PCA cable.
2. Check the Printmech PCA.
SE Code: 12.26:10 – Printmech: Hannibal1 24V open circuit. Check APS relief valve,
SVS motor and Rack engage motor
Problem description:
The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the APS relief valve, SVS motor and Rack engage motor.
2. Check the Printmech PCA.
SE Code: 12.27:10 – Printmech: Hannibal2 24V open circuit. Check Spit-on roller
motor and Primer motor
Problem description:
The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
ENWW Continuable and non-continuable error codes 83