The Curing System Monitor utility displays all the parameters of the curing system.
Temperature at each curing module (Target 120oC)
Fan revolutions for each curing module
Curing chamber pressure (target 3.2)
Power applied
Input line voltage
Procedure
1. Go to Service Menu > 1 Service Utilities > 1.8 Heating and Curing Menu > 1.8.1 Curing System Monitor.
2. Make sure that substrate is unloaded, and press OK.
3. The Front Panel shows current information related to the curing module. When the target is reached
you can press OK to finish the test. The printer cools down before finishing the test.
1.8.2 Curing plate cleaning
Description
Guides the service engineer through the cleaning process, it must be performed after the SMK3 intervention.
1.8.3 Curing homogeneity calibration
Description
Every curing module can be calibrated by adding a temperature offset to the temperature read by each one
of the curing sensors. Calibration has been already performed at manufactory and set as default.
The test:
1. Show Calibration:
Shows current and factory calibration values for each curing module.
2. Perform Manual Calibration:
Prints calibration plot with current calibration values and allows to set new current calibration
values.
3. Restore Factory Calibration:
Sets all current values to factory calibration.
4. Disable Calibration:
Sets all current values to zero, no offset will be applied.
1.9 Show Test Messages
Description
Explains how to enter the diagnostics TLC mode.
Procedure
1. Go to Service Menu > 1 Service Utilities > 1.9 Show Test Messages.
2. Press OK to exit.
172 Chapter 4 Service Tests, Utilities, and Calibrations ENWW