5. Reseat/Replace Curing Resistors.
6. Reseat/Replace Curing Temperature Sensors.
7. Reseat/Replace Curing Pressure Sensor.
SE Code: 16.02:00 – Curing system: cool down timeout
Problem description:
Ambient temperature above 30oC Fans (Curing, Air Curtain, PZ).
Corrective action:
Service engineer:
1. The environmental ambient temperature is too hot or is outside the operational specification of the
printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters
etc.
2. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
SE Code: 16.03:00 – Curing system: high temperature error
Problem description:
Ambient temperature above 30oC, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature
Sensor, Curing Pressure Sensor.
Corrective action:
Service engineer:
1. The environmental ambient temperature is too hot or is outside the operational specification of the
printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters
etc.
2. Run Service "Curing system monitor”.
3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
4. Reseat/Replace Curing Resistors.
5. Reseat/Replace Curing Temperature Sensors.
6. Reseat/Replace Curing Pressure Sensor.
SE Code: 16.04:00 – Curing system: low temperature error
Problem description:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing
Temperature Sensor, Curing Pressure Sensor.
Corrective action:
Service engineer:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within
the printer's operating specifications; it should be higher than 15C for printer operation. If this is the
case, increase the ambient temperature of the printer's location.
2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation
Guide.
ENWW Continuable and non-continuable error codes 95