Restart the printer.
Service engineer:
1. Check that the Trailing Cable is not damaged.
2. Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA, and Engine
PCA.
3. Replace the Trailing Cable.
SE Code: 12.1:10 – The 12V provided from Printmech to Curing module PCA are out
of range (10,8V to 13,2V)
Problem description:
One or more of the components powered by the 12V at the Curing Control PCA are causing a short circuit. The
12V cable from Printmech to the Curing Control PCA has a problem.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech cable to the Curing module PCA.
2. Check the Printmech PCA.
SE Code: 12.2:10 – Printmech 24V_BULLI_1 to Curing module PCA out of range
Problem description:
The 24V cable from Printmech to Curing Control PCA has a problem. Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech cable to the Curing module PCA.
2. Check the Printmech PCA.
SE Code: 12.3:10 – Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
Problem description:
The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer: