Open circuit detected at array 1: At least one of the leds could be fused. Replace one of the inner lights
PCAs and check if the problem is solved. If not, continue the troubleshooting by replacing sequentially
another PCA. Use diagnostics utility to switch the array On & Off
SE Code: 89.2:10 – Inner light PCA array 2 disconnected
Problem description:
Printzone leds array 2 disconnected.
Corrective action:
Service engineer:
▲
Restart the printer.
Service engineer:
▲
Open circuit detected at array 2: At least one of the leds could be fused. Replace one of the inner lights
PCAs and check if the problem is solved. If not, continue the troubleshooting by replacing sequentially
another PCA. Use diagnostics utility to switch the array On & Off
SE Code: 94:01 – CLC failed because paper white point is out of valid range
Problem description:
Paper white point is out of valid range.
Corrective action:
Call agent:
▲
Ensure the loaded substrate is white and there aren't spots on it.
SE Code: 94:02 – CLC failed, inconsistencies in measures detected
Problem description:
Inconsistencies in CLC measures detected.
Corrective action:
Call agent:
1. Check substrate type selection in front panel corresponds to actual substrate loaded.
2. Retry calibration.
SE Code: 94:08 – Color Calibration failed
Problem description:
Color Calibration failed.
Corrective action:
Call agent:
▲
Try again or check user manual color calibration troubleshooting.
SE Code: 94:10 – CLC measures out of range
Problem description: