1. Check cable the Printmech to Curing module cable.
2. Check the Printmech PCA.
SE Code: 12.21:10 – Printmech: 24V to Curing module PCA open circuit
Problem description:
The 24V cable from Printmech to Curing Control PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Curing module PCA cable.
2. Check the Printmech PCA.
SE Code: 12.22:10 – Printmech: 12V to Vapor Removal PCA open circuit
Problem description:
The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Vapor Removal PCA cable.
2. Check the Printmech PCA.
SE Code: 12.23:10 – Printmech: 24V to Vapor Removal PCA open circuit
Problem description:
The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Vapor Removal PCA cable.
2. Check the Printmech PCA.
SE Code: 12.24:10 – Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans
and PZ fans open circuit
Problem description:
The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
82 Chapter 3 System error codes ENWW