1. Check the Inner lights array 2.
2. Check the Printmech PCA.
SE Code: 12.11:10 – Printmech: 24V to Interconnect failure. Check TUR, Right
aerosol fan and Primer valves
Problem description:
The 24V cable from Printmech to Interconnect PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Interconnect cable.
2. Check TUR, Right aerosol fan and Primer valves.
3. Check the Printmech PCA.
SE Code: 12.12:10 – Printmech: 24V Misc failure. Check Air pumps and Primer
valves switch
Problem description:
The 24V cable from Printmech to Air Pumps and Interconnect PCA has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
1. Check the Printmech to Air Pumps cable ,and to the primer valves switch.
2. Check the Air Pumps.
3. Check Primer valves switch.
4. Check the Printmech PCA.
SE Code: 12.13:10 – Printmech: 24V to Printzone fans failure
Problem description:
The 24V cable from Printmech to Printzone fans has a problem Printmech PCA is damaged.
Corrective action:
Call agent:
▲
Restart the printer.
Service engineer:
ENWW Continuable and non-continuable error codes 79