9. Remove four T-20 screws that attach the heater to the impinging pressure chamber
10. Slide out the heater module carefully, so as not to damage the heater coils.
Installation
●
During reassembly, be careful to orient the heater module correctly. There is an arrow to help, and also
physical poka-yoke.
Impinging air curtain
Removal
WARNING! Turn off the printer and disconnect both power cords.
1. Remove the Right impinging module cover on page 252.
2. Remove the
Left impinging module cover on page 251.
270 Chapter 8 Removal and installation ENWW