Malfunction or sensor failure: A PIP glitch or a presence error has been detected. Automatic diagnostic should
discard if it's a recoverable failure or not.
Corrective action:
Service engineer:
1. Remove the magenta ink cartridge and reinstall it into the printer.
2. Replace the magenta ink cartridge.
Service engineer:
1. Check that the ISS to magenta ink cartridge cable is not damaged and is correctly connected to the Ink
Supply Tubes PCA.
2. Replace the ISS to magenta ink cartridge cable.
SE Code: 25.2:10 – Bad contact detected in ISS slot LM floater
Problem description:
Malfunction or sensor failure: A PIP glitch or a presence error has been detected. Automatic diagnostic should
discard if it's a recoverable failure or not.
Corrective action:
Service engineer:
1. Remove the light magenta ink cartridge and reinstall it into the printer.
2. Replace the light magenta ink cartridge.
Service engineer:
1. Check that the ISS to light magenta ink cartridge cable is not damaged and is correctly connected to the
Ink Supply Tubes PCA.
2. Replace the ISS to light magenta ink cartridge cable.
SE Code: 25.3:10 – Bad contact detected in ISS slot LC floater
Problem description:
Malfunction or sensor failure: A PIP glitch or a presence error has been detected. Automatic diagnostic should
discard if it's a recoverable failure or not.
Corrective action:
Service engineer:
1. Remove the light cyan ink cartridge and reinstall it into the printer.
2. Replace the light cyan ink cartridge.
Service engineer:
1. Check that the ISS to light cyan ink cartridge cable is not damaged and is correctly connected to the Ink
Supply Tubes PCA.
2. Replace the ISS to light cyan ink cartridge cable.
ENWW Continuable and non-continuable error codes 109