7-56 Service Manual
5062
40X7168 10J0927 Paper path
cables
Deflector assembly
• System board connector:
JPP2
1. Remove the lower frame cable
cover. See “Lower frame cable
cover removal” on page 4-16.
2. Remove the staging deflector
assembly. See “Staging
deflector assembly removal”
on page 4-140.
3. Remove the LVPS to route the
cable through the hole in the
lower frame. See “Low-voltage
power supply (LVPS) removal”
on page 4-86.
10J0929 MPF sensor
cable
Multipurpose feeder
• System board connector:
JMPF1
1. Remove the MPF sensor plate
assembly. See “MPF sensor
plate assembly removal” on
page 4-108.
2. Remove the LVPS exit duct to
route the cable through the hole
in the lower frame. See “LVPS
exit duct removal” on
page 4-89.
10J0933 Autocomp
W2W cable
Behind Tray 1, between MPF
redrive gears and rear frame
• System board connector:
JTRAY1
See “MPF drive assembly
removal” on page 4-106.
10J0935 Duplex motor
cable
Left access door
• System board connector:
JDUPL1
See “Staging paper path
reference edge assembly
removal” on page 4-142.
10J0936 Staging motor
cable
Left access door
System board connector:
JSTAG1
See “Staging paper path
reference edge assembly
removal” on page 4-142.
Note: Use a cable tie to attach the
toroid to the new cable and frame
bracket.
Cable location table
P/N item number Description Location To access