Parts catalog 7-55
5062
Cable and thermistor location table
Using the following table, locate the part you need to replace, and then go to the listed removal to find instructions
for accessing the cable or thermistor.
Cable location table
P/N item number Description Location To access
40X7165 10J0938 Fuser system
card and
LVPS cable
Fuser
• System board connector:
JFSR1
See “Fuser system card and
LVPS cable removal” on
page 4-67.
40X7166 10J0944 ITU
autoconnect
cable
Right frame
• System board connector:
JITM1
See “ITU autoconnect removal”
on page 4-78.
40X7167 10J0930 BLDC K & ITU
cable
EP drive
• System board connector:
JKI1
See “EP drive assembly removal”
on page 4-56.
Note: Use cable ties to attach the
toroids to the new cables as you
replace them.
10J0931 BLDC Y &
fuser cable
EP drive
• System board connector:
JYF1
10J0932 BLDC C & M
cable
EP drive
• System board connector:
JCM1
10J0940 M+K cartridge
metering cable
Cartridge memory blocks
• System board connector:
JCMKM1
See “Cartridge metering cable
removal” on page 4-46.
10J0955 C+Y cartridge
metering cable
Cat ridge memory blocks
• System board connector:
JCMCY1