Beta Draft Confidential
Configuring ATM Over MPLS Trunks
Configuring ATMoMPLS Trunk Logical Ports
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000 1/19/058-35
3. In the LPort Type field, select ATMoMPLS Trunk from the pull-down list. This is 
the only available LPort Type if an ATMoMPLS UNI or ATMoMPLS NNI feeder 
logical port has been created on the physical port. All non-ATM-related 
parameters are disabled. 
When you configure logical ports, the Add Logical Port dialog box contains a 
variety of parameters that you must specify. During this procedure, use the various 
tabs in the Add Logical Port dialog box to configure General, Administrative, 
QoS, and Traffic Descriptors parameters for the ATMoMPLS Trunk logical port. 
For ATMoMPLS Trunk logical ports, the next available unique Trunk ID is 
assigned by the NMS based on the trunk ID bits in the feeder logical port 
configuration. You can configure the Trunk ID value if desired using the General 
tab. 
Refer to the following sections for information about the attributes: 
– “ATMoMPLS Trunk Logical Port General Attributes” on page 8-35
– “ATMoMPLS Trunk Logical Port Administrative Attributes” on page 8-37
– “ATMoMPLS Trunk Logical Port QoS Attributes” on page 8-40
– “ATMoMPLS Trunk Logical Port Traffic Descriptor Attributes” on page 8-42
4. In the Add Logical Port dialog box, click OK to add the ATMoMPLS Trunk 
logical port. 
If bi-directional APS is enabled on the physical port, the logical port is created on both 
physical ports of the APS pair. 
ATMoMPLS Trunk Logical Port General Attributes
For ATMoMPLS Trunk logical ports, you must configure the Trunk ID field in the 
General tab. The next available unique Trunk ID is assigned by Navis EMS-CBGX 
based on the trunk ID bits in the feeder logical port configuration. 
The Trunk ID bits field contains a read-only value that was configured during the 
definition of the ATMoMPLS UNI or ATMoMPLS NNI feeder port.