Table F-3. Errors Encountered During Circuit Delete Procedure
Type of Failure SNMP Set Failure Reason Available Choices
Standard PVC – 1st switch
unreachable (higher-numbered
node)
Redirect PVC – Pivot switch
unreachable
The SNMP request timed out
(1st [or Pivot] endpoint
identified).
Abort – Discontinue attempt to delete circuit
(NMS database, switches, and out-of-sync
status unmodified).
Ignore – Discontinue attempt to delete
circuit, but delete the circuit from the NMS
database (circuit not deleted on either
switch; both endpoint cards marked
out-of-sync). PRAM sync of endpoint cards
will delete circuit on switches.
Retry – Attempt to delete the circuit again.
Standard PVC – 2nd switch
unreachable (lower-numbered
node)
Redirect PVC – Primary or
Secondary switch unreachable
The SNMP request timed out
(2nd [or Primary or
Secondary] endpoint
identified).
Abort – Discontinue attempt to delete circuit
(NMS database unmodified, circuit deleted
on 1st [or Pivot] switch but left dangling on
2nd [or Primary or Secondary] switch;
nothing marked out-of-sync). PRAM sync
of cards will restore the circuit on switches.
Ignore – Discontinue attempt to delete
circuit, but delete the circuit from the NMS
database (circuit deleted on 1st [or Pivot]
switch but left dangling on 2nd [or Primary
or Secondary] switch; both endpoint cards
marked out-of-sync). PRAM sync of
endpoint cards will delete circuit on
switches.
Retry – Attempt to delete the circuit again,
which now will not be able to succeed
completely.
Note: Retry process starts with 1st (or
Pivot) switch, which has a deleted circuit
that results in an error message. See the next
table row for more information.