EasyManuals Logo

Lucent Technologies CBX 3500 User Manual

Lucent Technologies CBX 3500
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #839 background imageLoading...
Page #839 background image
Beta Draft Confidential
Reliable Scalable Circuit
Circuit Delete Errors
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000 1/19/05F-7
Table F-3. Errors Encountered During Circuit Delete Procedure
Type of Failure SNMP Set Failure Reason Available Choices
Standard PVC – 1st switch
unreachable (higher-numbered
node)
Redirect PVC – Pivot switch
unreachable
The SNMP request timed out
(1st [or Pivot] endpoint
identified).
Abort – Discontinue attempt to delete circuit
(NMS database, switches, and out-of-sync
status unmodified).
Ignore – Discontinue attempt to delete
circuit, but delete the circuit from the NMS
database (circuit not deleted on either
switch; both endpoint cards marked
out-of-sync). PRAM sync of endpoint cards
will delete circuit on switches.
Retry – Attempt to delete the circuit again.
Standard PVC – 2nd switch
unreachable (lower-numbered
node)
Redirect PVC – Primary or
Secondary switch unreachable
The SNMP request timed out
(2nd [or Primary or
Secondary] endpoint
identified).
Abort – Discontinue attempt to delete circuit
(NMS database unmodified, circuit deleted
on 1st [or Pivot] switch but left dangling on
2nd [or Primary or Secondary] switch;
nothing marked out-of-sync). PRAM sync
of cards will restore the circuit on switches.
Ignore – Discontinue attempt to delete
circuit, but delete the circuit from the NMS
database (circuit deleted on 1st [or Pivot]
switch but left dangling on 2nd [or Primary
or Secondary] switch; both endpoint cards
marked out-of-sync). PRAM sync of
endpoint cards will delete circuit on
switches.
Retry – Attempt to delete the circuit again,
which now will not be able to succeed
completely.
Note: Retry process starts with 1st (or
Pivot) switch, which has a deleted circuit
that results in an error message. See the next
table row for more information.

Table of Contents

Other manuals for Lucent Technologies CBX 3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies CBX 3500 and is the answer not in the manual?

Lucent Technologies CBX 3500 Specifications

General IconGeneral
BrandLucent Technologies
ModelCBX 3500
CategorySwitch
LanguageEnglish

Related product manuals