Configuring Fault-tolerant PVCs
Configuring APS Resilient UNI
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000 1/19/0514-13
Defining the APS Fault-tolerant PVC/Resilient UNI Configuration
If the working port fails, the APS fault-tolerant PVC/resilient UNI software
automatically moves the Service Name endpoint to the protection (backup) port. Use
the following instructions to define the APS fault-tolerant PVC/resilient UNI
configuration between two working ports:
1. Complete the steps described in “Creating Service Names” on page 14-4 to assign
a Service Name to one of the working/ATM UNI logical port endpoints. A
different Service Name must be used if backing up the working APS port on the
other side of a fault-tolerant PVC.
2. Continue with the instructions in “Defining a Point-to-Point Circuit Connection”
on page 10-13 to configure the fault-tolerant PVC.