Configuring SPVCs
Restarting an Offnet Circuit
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000 1/19/0518-29
Restarting an Offnet Circuit
An offnet circuit can be restarted from the Navis EMS-CBGX switch navigation
panel. Restarting an offnet circuit is useful when connecting with a new route and/or
path. The circuit must be in a managed state for the Restart option to be available.
Restart is not available for PMP offnet circuits.
To restart an offnet circuit:
1. Expand the Circuits node.
2. Expand the Offnet Circuits class node.
3. Right-click on the Offnet Circuit you wish to restart and select Restart from the
pop-up menu.
The Restart option will only be available if the circuit is in a managed state.
4. Choose Yes to continue with the Restart.
An Admin Down and Admin Up command is sent to the selected offnet circuit.