Command reference
R&S
®
ZNA
1565User Manual 1178.6462.02 ─ 29
SOURce<Ch>:POWer:CORRection:GENerator<Gen>[:STATe].........................................1571
SOURce<Ch>:POWer<PhyPt>:CORRection:HARMonic[:ACQuire]................................... 1571
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:LTONe[:ACQuire]......................1572
SOURce<Ch>:POWer:CORRection:IMODulation:METHod.............................................. 1573
SOURce<Ch>:POWer:CORRection:IMODulation:PORT.................................................. 1574
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:UTONe[:ACQuire].....................1574
SOURce:POWer:CORRection:NREadings......................................................................1574
SOURce<Ch>:POWer:CORRection:OSOurces[:STATe]................................................... 1575
SOURce:POWer:CORRection:PMETer:ID...................................................................... 1575
SOURce:POWer:CORRection:PPOWer......................................................................... 1575
SOURce:POWer:CORRection:PPOWer:PATTenuation.....................................................1576
SOURce:POWer:CORRection:PSELect......................................................................... 1576
SOURce<Ch>:POWer<PhyPt>:CORRection:STATe........................................................ 1577
SOURce<Ch>:POWer<PhyPt>:CORRection:UPORt:STATe............................................. 1577
SOURce<Ch>:POWer:CORRection[:ACQuire] <SourceType>[, <SourcePort>[,
<CalOnlyPortFreq>]]
Selects the source for the source power calibration, starts and applies the source
power calibration.
Note: The command cannot be used unless a power meter is connected via GPIB bus,
USB or LAN interface and configured in the "External Power Meters" dialog.
Suffix:
<Ch>
.
Calibrated channel number
Setting parameters:
<SourceType> PORT | GENerator | A1 | A2 | A3 | A4 | ESRC1 | ESRC2 | CLO |
UPORt
PORT – analyzer port is the source of the calibrated wave.
GENerator – external generator is the source.
The port and generator numbers are specified by means of the
<SourcePort> parameter.
A1 | A2 | A3 | A4 – direct analyzer port selection. The parame-
ters A1 and A2 are ZVR-compatible. No additional port number
parameter needs to be specified.
ESRC1 | ESRC2 – direct external generator selection. The
parameters are ZVR-compatible. No additional parameters need
to be specified.
CLO – the optional (converter) LO Out port.
UPORt – can only be used on a 2-port R&S ZNAxx with second
internal source and internal combiner. If the internal combiner is
used (SOURce<Ch>:COMBiner INTernal),
SOURce<Ch>:POWer:CORRection UPORt, 2 performs a
source flatness calibration of the combiner upper port 2. The cal-
ibration can be enabled using SOURce<Ch>:POWer2:CORRec
tion:UPORt:STATe ON.
SCPI command reference