3-4
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 3 Connect the PC and Log into the GUI
NTP- D260 Set Up CTC Computer for Local Craft Connection to the ONS 15454 SDH
Step 2 Connect a straight-through (CAT-5) LAN cable from the PC or Solaris workstation NIC to one of the
following:
• RJ-45 (LAN) port on the active or standby TCC2/TCC2P card
• RJ-45 jack on the MIC-C/T/P FMEC
• RJ-45 (LAN) port on a hub or switch to which the ONS 15454 SDH is physically connected
Note For instructions about crimping your own straight-through (CAT-5) LAN cables, refer to the
Cisco ONS 15454 SDH Troubleshooting Guide.
Note For initial shelf turn-up, you should connect your PC directly to the LAN port on the
ONS 15454 TCC2/TCC2P card.
Step 3 Continue with the “NTP-D23 Log into the ONS 15454 SDH GUI” procedure on page 3-7, if applicable.
Stop. You have completed this procedure.
• You are connecting from a Windows PC.
• All nodes that you will access run Software
Release 3.3 or later.
• You will connect to ONS 15454 SDH nodes at different
locations and times and do not wish to reconfigure
your PC IP settings each time.
• You do not need to access or use non-ONS 15454 SDH
applications such as ping and tracert (trace route).
• You will connect to the ONS 15454 SDH
TCC2/TCC2P Ethernet port or FMEC LAN pins either
directly or through a hub.
DLP-D52 Set Up a Windows PC for Craft
Connection to an ONS 15454 SDH Using
Automatic Host Detection, page 17-42
• You are connecting from a Solaris Workstation.
• You will connect to one ONS 15454 SDH.
• You need to access non-ONS 15454 SDH applications
such as ping and tracert (trace route).
DLP-D53 Set Up a Solaris Workstation
for a Craft Connection to an
ONS 15454 SDH, page 17-45
Table 3-1 CTC Computer Setup for Local Craft Connection to the ONS 15454 SDH (continued)
CTC Connection Environment CTC Computer Setup Task