6-63
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D190 Create a Unidirectional High-Order Circuit with Multiple Drops
Step 19 Click Finish. If the path does not meet the specified path diversity requirement, CTC shows an error
message and allows you to change the circuit path. If you entered more than 1 in the Number of Circuits
field, the Circuit Creation dialog box appears after the circuit is created so you can create the remaining
circuits. Repeat Steps 6 through 18 for each additional circuit.
Step 20 When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
appear in the window.
Step 21 Complete the following as necessary. Skip this step if you built a test circuit.
a. Complete the “NTP-D62 Test High-Order Circuits” procedure on page 6-66.
b. Complete the “NTP-D149 Test G-Series Circuits” procedure on page 6-95.
Stop. You have completed this procedure.
NTP-D190 Create a Unidirectional High-Order Circuit with
Multiple Drops
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49 at an ONS 15454 SDH on the network
where you will create the circuit. If you are already logged in, continue with Step 2.
Step 2 If you want to assign a name to the tunnel source and destination ports before you create the circuit,
complete the “DLP-D314 Assign a Name to a Port” task on page 20-7. If you want CTC to assign a name
automatically based on circuit type, node name, and sequence number, continue with Step 3.
Step 3 From the View menu, choose Go to Network View.
Step 4 Click the Circuits tab, then click Create.
Step 5 In the Circuit Creation dialog box, complete the following fields:
Circuit Type—Choose VC_HO_PATH_CIRCUIT.
Number of Circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
Step 6 Click Next.
Step 7 Define the circuit attributes:
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Purpose This procedure creates a unidirectional STM-N circuit with multiple traffic
drops (circuit destinations).
Tools/Equipment None
Prerequisite Procedures NTP-D127 Verify Network Turn-Up, page 6-5
Required/As Needed As needed
Onsite/Remote Onsite or remote