DLP- D5 Mount the Shelf Assembly in a Rack (One Person)
Step 6 In the Circuit Source area, complete the following:
Node—Choose the source node.
Slot—Choose the source slot.
Port—If displayed, choose the source port.
Channel—Displays IPT (D1-D3).
Step 7 Click Next.
Step 8 In the Circuit Destination area, complete the following:
Node—Choose the destination node.
Slot—Choose the destination slot.
Port—If displayed, choose the destination port.
Channel—Displays IPT (D1-D3).
Step 9 Click Finish.
Step 10 Put the ports that are hosting the IP-encapsulated tunnel in service. See the “DLP-D214 Change the
Service State for a Port” task on page 19-10 for instructions.
Step 11 Return to your originating procedure (NTP).
DLP-D5 Mount the Shelf Assembly in a Rack (One Person)
Note The ONS 15454 SDH requires 616.5 mm (24.24 inch) minimum of vertical rack space and 25 mm
(1 inch) below the installed shelf assembly to allow air flow to the fan intake. If a second
ONS 15454 SDH is installed above a shelf assembly, the air ramp between the shelves provides space
for air flow. To ensure the mounting is secure, use two to four M6 mounting screws for each side of the
shelf assembly. A shelf assembly should be mounted at the bottom of the rack if it is the only unit in the
rack.
Step 1 Verify that the chassis fuses rating does not exceed 30A.
Step 2 Ensure that the shelf assembly is set for the desired rack size. Figure 17-1 shows the rack-mounting
position for the ONS 15454 SDH.
Purpose This task allows one person to mount the shelf assembly in a rack.
Tools/Equipment Pinned hex tool
Two M6 x 20 socket set screws
Eight M6 x20 pan-head Phillips mounting screws
#2 Phillips screwdriver
Prerequisite Procedures NTP-D1 Unpack and Inspect the ONS 15454 SDH Shelf Assembly, page
1-4
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None