EasyManua.ls Logo

Cisco ONS 15454 SDH - CHAPTER 13 Convert Network Configurations; Before You Begin

Cisco ONS 15454 SDH
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER
1-1
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
1
Install the Shelf and FMECs
This chapter explains how to install the Cisco ONS 15454 SDH shelf assembly. For a summary of the
tools and equipment required for installation, see the “Required Tools and Equipment” section on
page 1-2.
Before You Begin
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs). Read
the installation procedures and precautions before you install the ONS 15454 SDH and connect the
power source.
1. NTP-D1 Unpack and Inspect the ONS 15454 SDH Shelf Assembly, page 1-4—Complete this
procedure before continuing with the “NTP-D2 Install the Shelf Assembly” procedure on page 1-5.
2. NTP-D2 Install the Shelf Assembly, page 1-5—Complete this procedure to install the shelf
assembly in a rack.
3. NTP-D3 Open and Remove the Front Door, page 1-6—Complete this procedure to access the
equipment before continuing with other procedures in this chapter.
4. NTP-D219 Open and Remove the FMEC Cover, page 1-7—Complete this procedure to access the
electrical facility connection assembly (EFCA) for the front mount electrical connections (FMECs)
before continuing with other procedures in this chapter.
5. NTP-D220 Install the Power and Signal FMECs, page 1-7—Complete this procedure if you plan to
install electrical cards. This procedure is a prerequisite to the “NTP-D224 Install the Electrical Card
Cables on the FMECs” procedure on page 1-16.
6. NTP-D6 Install the Power and Ground, page 1-10—Complete this procedure before continuing with
the “NTP-D7 Install the Fan-Tray Assembly” procedure on page 1-11.
7. NTP-D7 Install the Fan-Tray Assembly, page 1-11—Complete this procedure to install the fan-tray
assembly in the shelf.
8. NTP-D222 Install the E1-75/120 Conversion Panel, page 1-13—Complete this procedure if you use
the E1-42 card and plan to use 75-ohm unbalanced interfaces.
9. NTP-D223 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections, page 1-15—Complete
as needed to set up wire-wrap pin connections and craft connections.
10. NTP-D224 Install the Electrical Card Cables on the FMECs, page 1-16—Complete this procedure
if you will install electrical cards.
11. NTP-D10 Route Electrical Cables, page 1-16—Complete as needed.