Chapter 1 Install the Shelf and FMECs
NTP- D1 Unpack and Inspect the ONS 15454 SDH Shelf Assembly
Note Ring runs are not provided by Cisco and can hinder side-by-side shelf installation where space is limited.
Tools Needed
To install the ONS 15454 SDH, you need the following tools:
#2 Phillips screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
Video fiber connector inspection instrument
CLETOP cleaning cassette
Crimping tool—This tool must be large enough to accommodate the girth of the grounding lug when
you crimp the grounding cable into the lug.
Wire stripping tool
Test Equipment
To install the ONS 15454 SDH, you need the following test equipment:
Voltmeter
Power meter (only for use with fiber optics)
Bit error rate (BER) tester for E1-N-14, E1-42, E3-12, DS3i-N-12, STM1E-12, and FMEC cards
NTP-D1 Unpack and Inspect the ONS 15454 SDH Shelf Assembly
Step 1 Complete the “DLP-D1 Unpack and Verify the Shelf Assembly” task on page 17-1.
Step 2 Complete the “DLP-D2 Inspect the Shelf Assembly” task on page 17-2.
Step 3 Continue with the “NTP-D2 Install the Shelf Assembly” procedure on page 1-5.
Stop. You have completed this procedure.
Purpose This procedure unpacks the ONS 15454 SDH and verifies the contents.
Tools/Equipment Pinned hex (Allen) key for front door
Prerequisite Procedures None
Required/As Needed Required
Onsite/Remote Onsite
Security Level None