19-6
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 19 DLPs D200 to D299
DLP- D209 Change External Controls Using the AIC-I Card
Step 4 Modify any of the following fields for each external device wired to the ONS 15454 SDH MIC-A/P card.
For definitions of these fields, see the “NTP-D247 Provision External Alarms and Controls on the Alarm
Interface Controller–International” procedure on page 9-8.
• Enabled
• Alarm Type
• Severity
• Virtual Wire
• Raised When
• Description
Step 5 To provision additional devices, complete Step 4 for each additional device.
Step 6 Click Apply.
Step 7 Return to your originating procedure (NTP).
DLP-D209 Change External Controls Using the AIC-I Card
Step 1 Verify the external control relays to the MIC-A/P card connector. See the “DLP-D324 Install Alarm
Cables on the MIC-A/P” task on page 20-12 for more information.
Step 2 In node view, double-click the AIC-I card to display it in card view.
Step 3 On the External Controls subtab, modify any of the following fields for each external control wired to
the ONS 15454 SDH MIC-A/P card. For definitions of these fields, see the “NTP-D247 Provision
External Alarms and Controls on the Alarm Interface Controller–International” procedure on page 9-8.
• Enabled
• Trigger Type
• Control Type
• Description
Step 4 To provision additional controls, complete Step 3 for each additional device.
Step 5 Click Apply.
Step 6 Return to your originating procedure (NTP).
Purpose This task changes the external control settings on the AIC-I card.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher